RIT series AC / DC Residual Current Transducer

RIT series AC / DC residual current transducer products were developed on the basis of Multi-Point Zero Flux Gate technology, which can be applied for both AC and DC residual current measurement application. 

RIT series current transducer is designed for measuring the small DC/AC current from 0.01A to 5A, and output with voltage. It has been used for vacuum coating and data center power supply systems (Trusted by Vertiv Technology Co., Ltd). 

 

MGW, as the global partner with Hangzhi, supply Hangzhi current measurement products and services to customer globally, and exclusively in Australia and New Zealand. 

Residual current transducer

Hangzhi Residual Current Transducer

Catalog of AC / DC Residual current transducers

Residual current transducer

RIT001, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC0.01;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±1V

Accuracy: 1%;

Linearity: 0.2%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT002, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC0.02;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±1V

Accuracy: 1%;

Linearity: 0.2%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT005, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC0.05;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±1V

Accuracy: 1%;

Linearity: 0.1%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT01, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC0.1A;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±2V

Accuracy: 0.2%;

Linearity: 0.1%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT05, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC0.5A;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±2V

Accuracy: 0.2%;

Linearity: 0.1%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT1, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC1A;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±2V

Accuracy: 0.2%;

Linearity: 0.1%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT2, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC2A;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±2V

Accuracy: 0.2%;

Linearity: 0.1%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT3, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC3A;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±3V

Accuracy: 0.2%;

Linearity: 0.1%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃

Residual current transducer

RIT5, Residual  Current Transducer, AC & DC

Primary Nominal Current: DC5A;

Overload Capacity: 200% for 1 minute

Power Supply: DC14.2V to 15.8V

Output Voltage: ±5V

Accuracy: 0.2%;

Linearity: 0.2%;

Zero Offset Voltage: ±10mV

Dynamic Response Time: 2ms

Frequency bandwidth
(-3dB): up to 100KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 85℃