HIT series AC / DC Substituting Hall Effect Current Transducer

HIT series AC / DC Hall effect substituting current transducer products were developed on the basis of Multi-Point Zero Flux Gate technology, which can be applied for both AC and DC current measurement application. All HIT current transducer products are CE EMC & RoHS compliant. 

They are extremely cost-effective solutions for current measurement, with its low cost similar to hall effect current transducers, but with much better performance in accuracy, linearity, response time, temperature & zero drift terms. So, they have been widely used industrial motor drive, UPS, Welding, Robot, Hoist, Elevator etc. 

MGW, as the global partner with Hangzhi, supply Hangzhi current measurement products and services to customer globally, and exclusively in Australia and New Zealand. 

substituting hall effect current transducer

HIT Series hall effect substituting current transducer

Catalog of AC / DC Substituting Hall Effect Current sensors
Transducers

HIT500 AC & DC substituting hall effect current transducer

Substituting Hall Effect Current Transducer, HIT60, AC & DC

Primary Nominal Current: DC70A, AC50A;

Overload Capacity: DC150A for 1 minute

Power Supply: DC14.2V to 15.8V

Ratio: 1000:1

Secondary Burden Resistance: 20 to 50Ω

Accuracy: 0.05%;

Linearity: 50ppm;

Current Change Rate: 100A/us

Frequency bandwidth
(-3dB): up to 200KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 80℃

HIT500 AC & DC substituting hall effect current transducer

Substituting Hall Effect Current Transducer, HIT100, AC & DC

Primary Nominal Current: DC141A, AC100A;

Overload Capacity: DC150A for 1 minute

Power Supply: DC14.2V to 15.8V

Ratio: 1000:1

Secondary Burden Resistance: 10 ~ 40Ω

Accuracy: 0.05%;

Linearity: 50ppm;

Current Change Rate: 100A/us

Frequency bandwidth
(-3dB): up to 200KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 80℃

HIT500 AC & DC substituting hall effect current transducer

Substituting Hall Effect Current Transducer, HIT200, AC & DC

Primary Nominal Current: DC282A, AC200A;

Overload Capacity: DC350A for 1 minute

Power Supply: DC14.2V to 15.8V

Ratio: 2000:1

Secondary Burden Resistance: 20 ~ 25Ω

Accuracy: 0.05%;

Linearity: 50ppm;

Current Change Rate: 100A/us

Frequency bandwidth
(-3dB): up to 200KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 80℃

HIT500 AC & DC substituting hall effect current transducer

Substituting Hall Effect Current Transducer, HIT300, AC & DC

Primary Nominal Current: DC500A, AC300A;

Overload Capacity: DC600A for 1 minute

Power Supply: DC14.2V to 15.8V

Ratio: 3000:1

Secondary Burden Resistance: 10 ~ 20Ω

Accuracy: 0.05%;

Linearity: 50ppm;

Current Change Rate: 100A/us

Frequency bandwidth
(-3dB): up to 200KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 80℃

Substituting Hall Effect Current Transducer, HIT500, AC & DC

Primary Nominal Current: DC700A, AC500A;

Overload Capacity: DC770A for 1 minute

Power Supply: DC14.2V to 15.8V

Ratio: 2000:1

Secondary Burden Resistance: 4 ~ 5Ω

Accuracy: 0.05%;

Linearity: 50ppm;

Current Change Rate: 100A/us

Frequency bandwidth
(-3dB): up to 200KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 80℃

Substituting Hall Effect Current Transducer, HIT600, AC & DC

Primary Nominal Current: DC824A, AC600A;

Overload Capacity: DC660A for 1 minute

Power Supply: DC14.2V to 15.8V

Ratio: 3000:1

Secondary Burden Resistance: 2 ~ 5Ω

Accuracy: 0.05%;

Linearity: 50ppm;

Current Change Rate: 100A/us

Frequency bandwidth
(-3dB): up to 200KHz

Insulation Voltage (Between primary and secondary): 5KV

Operation Temperature Range: -40 ~ 80℃